        TR-900J Multi-Parameter Patient Monitor
        Release time:2015-07-10 Author:admin Source:

         

         

        ◆7 inch color TFT LCD display with high resolution.
        ◆For Adult, pediatrics and neonates.
        ◆All lead ECG can be stored,  100 VPC waveform recall
        ◆Intelligent pressure oscillation, import parts, high precision
        measurement, safety, and has over-voltage protection.
        ◆Freezing, and 72 hours trend chart and alarm function, 1000 NIBP
        measurement data storage. With the alarm playback function,
        playback before and after the alarm four seconds, eight seconds or 16
        seconds of the relevant waveform. Show the waveform of the recent
        data of 1 hour recalling waveform , all data can be stored down. Six
        kinds of optional interface : large font interface, standard interface,
        all lead ECG interface, respiratory oxygenation interface, trend chart
        interface , blood pressure trend interface. Alarm classification
        function.
        ◆Universal platform design, easy software upgrades, can connect
        with information workstation and compose to center information
        workstation.
        ◆Built-in storage battery and recorder.
        ◆ISO 9001:2000,ISO 13485:2003 certificate
        .
        ECG              Lead configuration: standard 3 leads RA, LA, LL,  
                               Lead mode: I, II, III  5 leads cable RA, LA, LL, RL, V, 
                               Lead mode: I,II,III,aVR,aVL,aVF,V
                               Gain : 0.25,0.5,1,2
                               Heart Rate range : 20 ~ 230bpm (beat/min)
                               Accuracy:  ±1% or ±1bpm, choosing the bigger one
         

                               Resolution: 1 bpm (beat/min)
                               Sensitivity: > 200 uV
                               Input impedance : > 5MΩ
          NIBP           Measurement time in continuous mode: 5 minutes
                               Range of pulse rate: 40-240bpm
                               Scope of measurement and accuracy:
                               Adult   Systolic pressure    50~240mmHg
                               Diastolic pressure   30~200mmHg
                               Mean pressure     22~180mmHg
                               Static state pressure range    0~300mmHg
                               Static state pressure accuracy:  ±3mmHg
                               Accuracy of blood pressure : maximum average error
                              ±5mmHg;maximum standard deviation  8mmHg
                               Protection of over pressure: Adult      300mmHg
                                                                                     Pediatrics   240mmHg
                                                                                     Neonate    150mmHg
        SPO2            Range of SPO2: 40%~100%
                               Resolution of SPO2: 1%
                               Accuracy of SPO2 : ≤±2%(90~99%)、≤±4%(70%~89%)、
                                                               ≤±6%(50%~69%)


         